40MPHAQ09XA3
40 = FAN COIL UNIT
MP = MODEL
H = HIGH WALL / SYSTEM TYPE
A = MAJOR SERIES
Q = HEAT PUMP / INDOOR FAN COIL TYPE
09 = 3/4 TON / NOMINAL CAPACITY
X = NOT USED
A = VARIATION
3 = 208/230-1-60 / VOLTAGE

The 40MPHA series ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selectionof fan coils permits creative solutions to design problems such as:
  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • hen adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork
  • Historical renovations or any application where preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.

BENEFITS
LOW SOUND LEVELS

When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since the outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 40MPHA ductless systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these high wall systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide years of trouble-free operation.
The high wall indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless system design allows individual room heating or cooling when required. There is no need to run large supply-air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY-TO-USE CONTROLS
The high wall units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless systems to your application is easily accomplished.
Adding a condensate pump accessory to the high wall fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

Weight37.48 Pounds (lbs)
Width35.2 Inches (In)
Height11.7 Inches (In)
Country of OriginCHN
Length9.8 Inches (In)
Blower Motor RPM650-1000
Blower Motor Speeds3
BrandCarrier
CertificationsAHRI, ETL, Energy Star
CFM1380
Circuit Breaker - Max Amps15
Circuit Breaker - Min Amps13
ColorWhite
Cooling Capacity5000-17000
Cooling Rated Capacity Btu/h9000
Cycle/Hertz60 Hz
Drain Connection Size3/4"
EER15
Heating Capacity10000-13000
Liquid Line Size (OD)1/4"
Maximum Fuse Size15
Maximum Piping Length98'
Minimum Circuit Amps13
PhaseSingle
Product Family40MPHA
Prop 65Yes
Rated Current Amps0.34
RefrigerantR-410a
SEER42
Suction Line Size (OD)3/8"
TierPerformance,Preferred™
Tonnage0.75
Voltage208-230 VAC