Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.

38MBRQ36A--3 - 3 Ton Single Zone Ductless Heat Pump 208-230/1/60

Item: 38MBRQ36A--3
MFR: 38MBRQ36A--3

Store Inventory

Sign in to see real-time inventory at the stores closest to you.
What’s the price?
Sign in for pricing.

Frequently Bought Together

Best Sellers

Pads Mounts & Blocks

Ductless Controls

Condensate Management

Thermostats & Controls

Refrigerant & Oils

Ductless Indoor Units

About This Product

Product Info

Description

38MBRQ36A--3
38 = OUTDOOR UNIT
MB = MODEL
R = OUTDOOR UNIT / UNIT TYPE:
Q=HEAT PUMP / SYSTEM TYPE:
36 = 3 TONS / NOMINAL CAPACITY
A = 1:1 / MAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNIT
-- = NOT USED
3 = 208/230-1-60 / VOLTAGE

A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 38MBR series ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The ductless system permits creative solutions to design problems such as:
  •  Add-ons to current space (an office or family room addition)
  •  Special space requirements
  •  When changes in the load cannot be handled by the existing system
  •  When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork
  •  Historical renovations or any application where preserving the look of the original structure is essential.
The ideal compliment to your ducted style ductless system when it is impractical or prohibitively expensive to use ductwork.
The compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technolog

LOW SOUND LEVELS
When noise is a concern, the ductless systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
When sound ordinances and proximity to neighbors demand quiet operation, the 38MBR unit is the right choice. The advanced, horizontal airflow design distributes air more evenly over the coil.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since 38MBR units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. Mounting brackets are standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 38MBR ductless systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide years of trouble-free operation.
The indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep (in some indoor models) feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless system design allows individual room heating or cooling when required. There is no need to run large supply-air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY-TO-USE CONTROLS
The indoor units have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless systems to your application is easily accomplished.
Adding a condensate pump accessory to the indoor fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS

All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

Weight136.47 Pounds (lbs)
Width37.24 Inches (In)
Height31.89 Inches (In)
Country of OriginCHN
Length16.14 Inches (In)
BrandBryant,Payne,Carrier
CertificationsAHRI Certified
Circuit Breaker - Max Amps50
ColorWhite
Condenser Motor HP1/6 HP
Condenser Motor RPM1050
Condenser Motor TypeDirect Drive
Cooling Capacity8500-38000
Cooling Rated Capacity Btu/h36000
Cycle/Hertz60 Hz
EER8.5
Heating Capacity9500-50000
InverterYes
Liquid Line FittingFlare
Liquid Line Size (OD)3/8"
Maximum Fuse Size50
Maximum Piping Length213'
Minimum Circuit Amps30
Number of HVAC Zones1
PhaseSingle
Product Family38MBR
Prop 65Yes
Rated Current Amps1.21
Rated Load Amps8.9
RefrigerantR-410a
SEER15
Suction Line FittingFlare
Suction Line Size (OD)5/8"
TierPerformance,Preferred™
Tonnage3
Voltage208-230 VAC
Warranty OfferedYes
Zone Capability1 Zone